Measurement & Dimensional Verification
We calibrate all measurement equipment through NATA-accredited laboratories (NATA is Australia's national measurement accreditation body), traceable to NMI primary standards. Our default is First Article Inspection on critical dimensions. Checks beyond that follow the inspection plan agreed at order.
For critical applications, we provide formal inspection reports or controlled sampling plans based on ISO 2859-1:1999 (Acceptance Quality Limit). 100% inspection of specified dimensions is available on request and quoted at time of order, documented and delivered with the order.